That particular windlass can be installed with or without the solenoid box if you use the high rated Lewmar toggle switch. That's the only model in the line that you can do that with. 25 Amp breaker is correct. If you don't use the solenoid you cant have a second station switch or foot switches at the bow. Don't up the breaker size, find the problem and correct.